All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C. 6 Pressure switches DRS 5 ES 0.5 - 5 bar G 1 / 4 “ 300 bar 250 V/4 A* DRS 10 ES 1 - 10 bar G 1 / 4 “ 300 bar 250 V/4 A* DRS 50 ES 10 - 50 bar G 1 / 4 “ 300 bar 250 V/4 A* DRS 100 ES 10 - 100 bar G 1 / 4 “ 300 bar 250 V/4 A* DRS 200 ES 50 - 200 bar G 1 / 4 “ 600 bar 250 V/4 A* Connectors for stainless steel pressure switch (please order separately) DRS STECKDOSE * at 30 V DC, ** type DRS 200 ES, controller using pistons Stainless steel pressure switches up to 200 bar Materials: Body: AISI 303, seal and diaphragms**: FKM Temperature range: -5°C to max. +120°C Switchback difference: 10 to 30% Protection class: IP 65 (clamps IP 00) Cable connection: Via flat connector 3 x 6.3 x 0.8 Optional: Diaphragms made of EPDM (-30°C to max. +120°C) -EP Ø 30 50 pressure switches connector F Order example: DRS 5 ES ** Standard type F Designation for the options: Diaphragms made of EPDM . . . -EP Vacuum switch --- VAKUS for vacuum -0.95 to -0.1 bar G 1 / 8 “ 20 bar 250 V/3.5 A* Pressure switches DRS 2 --- 0.2 - 2 bar G 1 / 4 “ 200 bar 250 V/2 A* DRS 5 DRSV 5 0.5 - 5 bar G 1 / 4 “ 200 bar 250 V/2 A* DRS 10 DRSV 10 1 - 10 bar G 1 / 4 “ 200 bar 250 V/2 A* DRS 20 --- 2 - 20 bar G 1 / 4 “ 200 bar 250 V/2 A* DRS 50 --- 5 - 50 bar G 1 / 4 “ 200 bar 250 V/2 A* DRS 100 --- 10 - 100 bar G 1 / 4 “ 200 bar 250 V/2 A* DRS 250 --- 25 - 250 bar G 1 / 4 “ 600 bar 250 V/2 A* DRS 400 --- 40 - 400 bar G 1 / 4 “ 600 bar 250 V/2 A* * for 30 V DC, ** settings range > 100 bar controller using pistons B 1 = design type 1: lateral adjustment screw, B 2 = design type 2: the setting can only be completed after removing the safety cap Materials: Body: Aluminium, diaphragms**: NBR (vacuum switch: ECO) Temperature range: -20°C to max. +100°C Switchback difference: 10 to 30% Protection class: IP 65, type B2: Elbow plug connection DIN 43560/EN 175301-803 (size 3, 4-pin) Media: Hydraulic oil, machine oil, turpentine, heating oil, air Lateral switchi ng poi n t adjust m e n t Pressure switches up to 400 bar type B 1 vacuum switch type B 2 type changer type NO/NC contact Materials: Body: Zinc-plated steel, seals/diaphragms: NBR Temperature range: -25°C to max. +85°C Switchback difference: 15 to 25% Protection class: IP 67 (clamps: IP 00) Cable connection: Via bayonet coupling, DIN 72585 (connector diameter 2.5 mm) Media: Hydraulic oil, machine oil, heating oil, air, water (only type DRSIP) Advantages: Ÿ Ideal for outdoor use in construction or farm equipment, as a protection class of IP 67 is achieved through the use of bayonet couplings. Pressure switches - with bayonet connections IP 67 up to 200 bar Type Changer DRSIP 2 0.3 - 2 bar G 1 / 4 “ 15 bar 42 V/5 A* DRSIP 10 1 - 10 bar G 1 / 4 “ 20 bar 42 V/5 A* DRSIP 70** 10 - 70 bar G 1 / 4 “ 120 bar 42 V/5 A* DRSIP 200** 50 - 200 bar G 1 / 4 “ 300 bar 42 V/5 A* DRSIPS 1 DRSIPO 1 0.1 - 1 bar G 1 / 4 “ 300 bar 42 V/100 VA DRSIPS 10 DRSIPO 10 1 - 10 bar G 1 / 4 “ 300 bar 42 V/100 VA DRSIPS 20 DRSIPO 20 10 - 20 bar G 1 / 4 “ 300 bar 42 V/100 VA DRSIPS 50 DRSIPO 50 20 - 50 bar G 1 / 4 “ 300 bar 42 V/100 VA DRSIPS 150** DRSIPO 150** 50 - 150 bar G 1 / 4 “ 600 bar 42 V/100 VA Connector, for pressure switch with bayonet connection DRSIP STECKDOSE (straight) DRSIP STECKDOSE 90 (angled) * for 30 V DC, ** controller using pistons, seal: UR (type DRSIPS 150 and DRSIPO 150: NBR) type DRSIP STECKDOSE type DRSIP STECKDOSE 90 ü Ø 30 65 Ø 27 49 NO contact NC contact Switching capacity Settings range Prot. against overpress. to Thread male Type changer Switching capacity Settings range Prot. against overpress.e to Type B 1 changer Type B 2 changer Thread female Switching capacity Settings range Prot. against overpress. to Thread male APH Techniek BV - Wateringen - T +31 (0)174 219 200 - sales@aphtechniek.nl - www.aphtechniek.nl 393

RkJQdWJsaXNoZXIy ODY1MjQ=