APH techniek
All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C. 6 Valves/distributors - Futura Ball valves with venting Futura model series up to 25 000 l/min Input pressure: 0 - 16 bar (model series 0: 0 - 12 bar) Function: 3/2 way shut-off valve w/ captured exhaust air. In closed state, can be locked using a padlock VHS 20 (pag. 641). Supply volume: Ball valve incl. silencer ATEX: Operating material without its own potential source of ignition in accordance with Directive 2014/34/EU (not model series 0) Coupling kit W 0 F KP 0 F or KPW 0 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F Type Thread H H1 L Model series 0 K 014 F G 1 / 4 “ 2300 76 51 43 Model series 1 K 14 F G 1 / 4 “ 1900 88 55 52 K 38 F G 3 / 8 “ 1900 88 55 52 Model series 2 K 382 F G 3 / 8 “ 11000 127 57 63 K 12 F G 1 / 2 “ 11000 127 57 63 Model series 4 K 34 F G 3 / 4 “ 25000 145 51 85 K 10 F G 1“ 25000 145 51 85 2 1 3 Coupling kit W 0 F KP 0 F or KPW 0 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F 3/2-way valves Futura model w/ manual emergency operation up to 12 500 l/min Input pressure: 2 - 10 bar, (pneumatically operated: 2 - 16 bar) Power consumption: 2.5W/3 VA (50Hz), protection category: IP 65 Supply volume: Valves incl. silencers L H1 H Valves Futura model series Materials: Body: Grivory® (PA 66), cover: POM, seals: NBR Temperature range: -10°C to max. +50°C Media: Oiled and unoiled compressed air, neutral gases Advantages: • Simple assembly of single components using coupling kits within a model series. • Delivery includes an exhaust silencer, if necessary 3 2 1 ü Thread H H1 L Model series 0 M CL 014 F 24V= M CL 014 F 230V P CL 014 F G 1 / 4 “ 2000 138* 45 43 Model series 1 M CL 14 F 24V= M CL 14 F 230V P CL 14 F G 1 / 4 “ 2000 118* 33 52 M CL 38 F 24V= M CL 38 F 230V P CL 38 F G 3 / 8 “ 2000 118* 33 52 Model series 2 M CL 382 F 24V= M CL 382 F 230V P CL 382 F G 3 / 8 “ 4300 150* 57 63 M CL 12 F 24V= M CL 12 F 230V P CL 12 F G 1 / 2 “ 4300 150* 57 63 Model series 4 M CL 34 F 24V= M CL 34 F 230V P CL 34 F G 3 / 4 “ 12500 178* 67 85 M CL 10 F 24V= M CL 10 F 230V P CL 10 F G 1“ 12500 178* 67 85 L H1 H L H1 H * for pneumatic actuation (G 1 / 8 “ ): 97 mm (model series 0), 70 mm (model series 1), 118 mm (model series 2), 150 mm (model series 4) Coupling kit W 0 F KP 0 F or KPW 0 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F Filler valves (start-up valves) Futura model series up to 10 000 l/min L H1 H Input pressure: 2.5 - 16 bar (model series 0: 2.5 - 12 bar) Function: The machines are allowed to breathe gradually via an orifice. Once the pressure attains a value of approx. 50% of the input pressure and the cylinders have gradually moved into their basic settings, the start-up valve switches over to maximum throughway. The speed of the pressure build-up can be controlled using an adjustment screw. ATEX: Operating material w/o its own potential source of ignition in acc. to Directive 2014/34/EU (not model series 0) Type Thread H H1 L Model series 0 BEFULL 014 F G 1 / 4 “ 2000 81 28 43 Model series 1 BEFULL 14 F G 1 / 4 “ 2000 78 33 52 BEFULL 38 F G 3 / 8 “ 2000 78 33 52 Model series 2 BEFULL 382 F G 3 / 8 “ 4500 112 58 63 BEFULL 12 F G 1 / 2 “ 4500 112 58 63 Model series 4 BEFULL 34 F G 3 / 4 “ 10000 112 54 85 BEFULL 10 F G 1“ 10000 112 54 85 Shut-off valves (e.t. ball valves ) must be installed before the filler valve! model series 1 model series 0/2/4 model series 0/1 model series 2 model series 4 Mounting bracket Type pneu- matic Type 24V DC Type 230V AC Mounting bracket Mounting bracket Flow l/min Flow l/min Flow l/min 334 APH Techniek BV - Wateringen - T +31 (0)174 219 200 - sales@aphtechniek.nl - www.aphtechniek.nl
RkJQdWJsaXNoZXIy ODY1MjQ=