APH techniek
All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C. 6 Service units - Futura Service units, 2-part, Futura model series 4 12 000 l/min 170 192 329 Max. condensate amount: 87 cm 3 Switch panel thread: M 50 x 1.5 Supply volume: Air unit, including 50 mm pressure gauge Own air consumption: Max. 1.5 l/min Oil metering at 1000 l/min: Approx. 1 - 2 drops/min Oil supply: 181 cm 3 Lubricator reaction limit (at 6 bar): 115 l/min ATEX: Operating material without its own potential source of ignition in accordance with Directive 2014/34/EU Optional: Version with metal container and inspection tube -M, automatic drain -AM, automatic drain closed when not pressurised (0 - 16 bar) -AMNC , safety version: With upstream lockable ball valve and filler valve -Si F Type Thread CL 34 F* G 3 / 4 “ 0.5 - 8 bar 0 - 10 bar CL 34-1 F G 3 / 4 “ 0.1 - 1 bar 0 - 1.6 bar CL 34-2 F G 3 / 4 “ 0.1 - 2 bar 0 - 2.5 bar CL 34-4 F G 3 / 4 “ 0.2 - 4 bar 0 - 6 bar CL 34-10 F G 3 / 4 “ 0.5 - 10 bar 0 - 16 bar CL 34-16 F G 3 / 4 “ 0.5 - 16 bar 0 - 25 bar CL 10 F* G 1“ 0.5 - 8 bar 0 - 10 bar CL 10-1 F G 1“ 0.1 - 1 bar 0 - 1.6 bar CL 10-2 F G 1“ 0.1 - 2 bar 0 - 2.5 bar CL 10-4 F G 1“ 0.2 - 4 bar 0 - 6 bar CL 10-10 F G 1“ 0.5 - 10 bar 0 - 16 bar CL 10-16 F G 1“ 0.5 - 16 bar 0 - 25 bar * standard series, please use preferentially as the regulation range can be applied universally Coupling kit W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F W 4 F KP 4 F or KPW 4 F Order example: CL 34 F ** Designation for the options: With metal container and inspection tube . . . . . . . . . . . . . -M With automatic drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . -AM With automatic drain, closed when depressurised (0 to 16 bar) . . . . . . . . . . . . . . -AMNC With upstream, lockable ball valve and filler valve . . . . . . . -Si F Standard type Service units, 2-part, Futura model series 2 3 500 l/min 126 147 257 Max. condensate amount: 49 cm 3 Switch panel thread: M 42 x 1.5 Supply volume: Air unit, including 50 mm pressure gauge Oil metering at 1000 l/min: Approx. 1 - 2 drops/min Oil supply: 80 cm 3 Lubricator reaction limit (at 6 bar): 70 l/min ATEX: Operating material without its own potential source of ignition in accordance with Directive 2014/34/EU Optional: Version with metal container and inspection tube -M, automatic drain -AM, automatic drain closed when not pressurised (0 - 16 bar) -AMNC , safety version: With upstream lockable ball valve and filler valve -Si F Type Thread CL 382 F* G 3 / 8 “ 0.5 - 8 bar 0 - 10 bar CL 382-1 F G 3 / 8 “ 0.1 - 1 bar 0 - 1.6 bar CL 382-2 F G 3 / 8 “ 0.1 - 2 bar 0 - 2.5 bar CL 382-4 F G 3 / 8 “ 0.2 - 4 bar 0 - 6 bar CL 382-10 F G 3 / 8 “ 0.5 - 10 bar 0 - 16 bar CL 382-16 F G 3 / 8 “ 0.5 - 16 bar 0 - 25 bar CL 12 F* G 1 / 2 “ 0.5 - 8 bar 0 - 10 bar CL 12-1 F G 1 / 2 “ 0.1 - 1 bar 0 - 1.6 bar CL 12-2 F G 1 / 2 “ 0.1 - 2 bar 0 - 2.5 bar CL 12-4 F G 1 / 2 “ 0.2 - 4 bar 0 - 6 bar CL 12-10 F G 1 / 2 “ 0.5 - 10 bar 0 - 16 bar CL 12-16 F G 1 / 2 “ 0.5 - 16 bar 0 - 25 bar * standard series, please use preferentially as the regulation range can be applied universally Coupling kit W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F Order example: CL 12 F ** Designation for the options: With metal container and inspection tube . . . . . . . . . . . . . -M With automatic drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . -AM With automatic drain, closed when depressurised (0 to 16 bar) . . . . . . . . . . . . . -AMNC With upstream, lockable ball valve and filler valve . . . . . . . -Si F Standard type Order example: CL 14 F Standard type F Designation for the options Order service units of the model series Multifix without "F” -F e. g.: CL 14 Pressure regula. range Pressure gauge display Mounting bracket Pressure regula. range Pressure gauge display Mounting bracket Contact us for service units of the model series Multifix APH Techniek BV - Wateringen - T +31 (0)174 219 200 - sales@aphtechniek.nl - www.aphtechniek.nl 331
RkJQdWJsaXNoZXIy ODY1MjQ=