APH techniek
All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C. 6 Service units - Futura Service units, 2-part, Futura model series 1 1 750 l/min 104 130 225 Max. condensate amount: 28 cm 3 Switch panel thread: M 36 x 1.5 Supply volume: Air unit, including 50 mm pressure gauge Oil metering at 1000 l/min: Approx. 1 - 2 drops/min Oil supply: 40 cm 3 Lubricator reaction limit (at 6 bar): 90 l/min ATEX: Operating material without its own potential source of ignition in accordance with Directive 2014/34/EU Optional: Version with metal container and inspection tube -M, automatic drain -AM, automatic drain closed when not pressurised (0 - 16 bar) -AMNC , safety version: With upstream lockable ball valve and filler valve -Si F Type Thread CL 14 F* G 1 / 4 “ 0.5 - 8 bar 0 - 10 bar CL 14-1 F G 1 / 4 “ 0.1 - 1 bar 0 - 1.6 bar CL 14-2 F G 1 / 4 “ 0.1 - 2 bar 0 - 2.5 bar CL 14-4 F G 1 / 4 “ 0.2 - 4 bar 0 - 6 bar CL 14-10 F G 1 / 4 “ 0.5 - 10 bar 0 - 16 bar CL 14-16 F G 1 / 4 “ 0.5 - 16 bar 0 - 25 bar CL 38 F* G 3 / 8 “ 0.5 - 8 bar 0 - 10 bar CL 38-1 F G 3 / 8 “ 0.1 - 1 bar 0 - 1.6 bar CL 38-2 F G 3 / 8 “ 0.1 - 2 bar 0 - 2.5 bar CL 38-4 F G 3 / 8 “ 0.2 - 4 bar 0 - 6 bar CL 38-10 F G 3 / 8 “ 0.5 - 10 bar 0 - 16 bar CL 38-16 F G 3 / 8 “ 0.5 - 16 bar 0 - 25 bar * standard series, please use preferentially as the regulation range can be applied universally Coupling kit W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F Order example: CL 14 F ** Designation for the options: With metal container and inspection tube . . . . . . . . . . . . . -M With automatic drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . -AM With automatic drain, closed when depressurised (0 to 16 bar) . . . . . . . . . . . . . . -AMNC With upstream, lockable ball valve and filler valve . . . . . . . -Si F Standard type Service units, 2-part, Futura model series Version: Filter regulator resettable, with attached lubricator Materials: Body: Grivory® (PA 66), spring hood: POM, diaphragms and seals: NBR, container: Polycarbonate Temperature range: -10°C to max. +50°C Input pressure: 1.5 - 16 bar (model series 0: 1.5 - 12 bar) Condensate draining: Semi-automatic 1) Pressure gauge connection: G 1 / 4 “ Pore width in the filter: 5 µm Media: Compressed air, neutral gases Advantages: Ÿ Automatic venting in the event of overpressure on the secondary side. Ÿ Simple assembly of single components using coupling kits within a model series. Ÿ Hand wheel can be locked by pressing down on it and bolted with a lock - please use VHS 20 (page 641). Ÿ Semi-automatic oil filling by connecting a hose to the bottom on the oil bowl (G 1 / 8 “). When the oil fill button is pressed, oil from the container will be sucked through the hose (not model series 0). ü Service units, 2-part, Futura model series 0 800 l/min 86 105 168 Max. condensate amount: 16 cm 3 Switch panel thread: M 30 x 1.5 Supply volume: Air unit, including pressure gauge Oil metering at 1000 l/min: Approx. 10 - 20 drops/min Oil supply: 35 cm 3 Lubricator reaction limit (at 6 bar): 26 l/min Optional: Version with metal container and without inspection tube -M, automatic drain -AM, automatic drain closed when not pressurised (0 - 12 bar) -AMNC F Thread CL 014 F* CL 014 FB* G 1 / 4 “ 0.5 - 8 bar 0 - 10 bar CL 014-4 F CL 014-4 FB G 1 / 4 “ 0.2 - 4 bar 0 - 6 bar CL 014-10 F CL 014-10 FB G 1 / 4 “ 0.5 - 10 bar 0 - 16 bar * standard series, please use in preference, as the regulation range is universally applicable, *** installation of a standard pressure gauge only possible with a pressure gauge adapter, display range of the compact pressure gauge: 0 to 12 bar, or 0 to 6 bar Coupling kit W 0 F KP 0 F or KPW 0 F W 0 F KP 0 F or KPW 0 F W 0 F KP 0 F or KPW 0 F Order example: CL 014 F ** Designation for the options: With metal container, without inspection tube . . . . . . . . . . . . . . . -M With automatic drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -AM With automatic drain, closed when depressurised (0 to 12 bar) . . -AMNC F Standard type 1) as soon as the inlet pressure falls below the mi- nimum input pressure, the drain valve opens automatically. The semi-automatic drain valve can be prevented from opening by screwing on the drain plug tightly. Garden hose couplings from page 178 Multi-Link distributor systems from page 157 Multiple couplings from page 41 Stainless steel screw connections from page 78 Pneumatic oil on page 574 Type with 40 mm standard press. gauge Pressure gauge display Mounting bracket Pressure regula. range Pressure gauge display Mounting bracket Type with compact pressure gauge *** Pressure regulation range 330 APH Techniek BV - Wateringen - T +31 (0)174 219 200 - sales@aphtechniek.nl - www.aphtechniek.nl
RkJQdWJsaXNoZXIy ODY1MjQ=