APH techniek
All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C. 5 Electrically actuated ball valves Ball valves with electric rotary actuators (sanitary design) up to 40 bar Advantages: Ÿ 2 additional limit switches Ÿ Torque cut-off Ÿ Variable voltage (DC or AC) Ÿ Manual emergency operation Ÿ Integrated heating in actuator housing Ball valve Materials: Housing: Brass nickel-plated, ball: Brass hard chrome-plated, ball seals: PTFE Temperature range: -20°C to max. +95°C Assembly flange conforming to ISO 5211 Operating range: Water, compressed air, vacuum (max. -0.9 bar), oils, fuels, heating oil, solvents, colours, paints, weak acids and alkalis Rotary actuator Electric rotary actuator with optical position indicator, manual emergency operation and switch room heating. Two additional limit switches are installed for further control requirements. An electronic torque limiting unit prevents da- mage in the event of overload. The manual emergency operation can be done without dismantling the external cladding. Do not use upside down! Temperature range: -20°C to max. +70°C Voltage: Type 230: 110 - 240V AC/DC, type 24: 24V AC/DC, (actuators can be operated with AC and DC voltage). Protection class: IP 65 Max. switchable pressure difference: 16 bar Power-on time: 75% Regulating time: Type 24: 19 sec., type 230: 16 sec. Thread DN PN* Actuator size** KH 14 ELS 230 KH 14 ELS 24 G 1 / 4 “ 10 65 40 bar 1-F03 KH 38 ELS 230 KH 38 ELS 24 G 3 / 8 “ 15 65 40 bar 1-F03 KH 12 ELS 230 KH 12 ELS 24 G 1 / 2 “ 15 65 40 bar 1-F03 KH 34 ELS 230 KH 34 ELS 24 G 3 / 4 “ 20 75 40 bar 1-F03 KH 10 ELS 230 KH 10 ELS 24 G 1“ 25 86 40 bar 1-F05-VK9 KH 114 ELS 230 KH 114 ELS 24 G 1 1 / 4 “ 32 95 32 bar 1-F05-VK9 KH 112 ELS 230 KH 112 ELS 24 G 1 1 / 2 “ 40 101 30 bar 1-F05-VK11 KH 20 ELS 230 KH 20 ELS 24 G 2“ 50 120 30 bar 1-F05-VK11 * max. switchable pressure difference: 16 bar, ** for dimensions and replacement actuators see page 310 ü Thread DN PN Actuator size* KH 14 ELi 230 Rp 1 / 4 “ 10 67 40 bar 2-F03 KH 38 ELi 230 Rp 3 / 8 “ 15 67 40 bar 2-F03 KH 12 ELi 230 G 1 / 2 “ 15 75 40 bar 2-F03 KH 34 ELi 230 G 3 / 4 “ 20 80 40 bar 2-F03 KH 10 ELi 230 G 1“ 25 90 40 bar 2-F03 KH 114 ELi 230 G 1 1 / 4 “ 32 110 40 bar 2-F05-VK11 KH 112 ELi 230 G 1 1 / 2 “ 38 120 40 bar 2-F05-VK11 KH 20 ELi 230 G 2“ 50 140 40 bar 2-F05 KH 212 ELi 230 G 2 1 / 2 “ 65 165 30 bar 4-F05 KH 30 ELi 230 G 3“ 76 188 25 bar 4-F07-VK14 KH 40 ELi 230 Rp 4“ 90 200 20 bar 4-F07-VK14 * for dimensions and replacement actuators see page 315 Ball valves with electric rotary actuators (industrial design) up to 40 bar Advantages: Ÿ 2 additional limit switches Ÿ Torque cut-off Ÿ Variable voltage (DC or AC) Ÿ Manual emergency operation Ÿ Integrated heating in actuator housing Ball valve Materials: Housing: Brass nickel-plated, ball: Brass hard chrome-plated, seal: PTFE Length according to DIN 3202-M3 (G 1 / 2 “ - G 2“), DVGW approval for G 1 / 2 “ - G 2“ (PN 5/MOP 5) Temperature range: -20°C to max. +160°C (G 2 1 / 2 “ - G 4“: max. +120°C), gas: -20°C to max. +60°C Operating range: Water, compressed air, vacuum (max. -0.9 bar), oils, fuels, heating oil, solvents, colours, paints, weak acids and alkalis Rotary actuator Electric rotary actuator with optical position indicator, manual emergency operation and switch room heating. Two addi- tional limit switches are installed for further control requirements. An electronic torque limiting unit prevents damage in the event of overload. The manual emergency operation can be done without dismantling the external cladding. Do not use upside down! Materials: Housing: PA 6 Temperature range: -20°C to max. +70°C Voltage: Type 230: 24 - 240V AC/DC, (actuators can be operated with AC and DC voltage). Protection class: IP 67 Power-on time: 75% Regulating time: 10 to 14 sec. Optional: Regulating time 140 sec. (only for actuator size 2) -140, "Battery Safety Return" for emergency closing NC (standard configuration) or emergency opening NO (changeover using jumpers) in case of power failure -BSR ü F Order example: KH 14 ELi 230 ** Designation for the options: Regulating time 140 sec. (only for actuator size 2) . . -140 Battery Safety Return . . . . . . . . . . . . . . . . . . . . . . . -BSR F Standard type Warning: With high media temperatures the actuator must be protected by a thermal bridge or cooled! Warning: With high media temperatures the actuator must be protected by a thermal bridge or cooled! Compressed air and water hoses from page 208 Threaded nozzles from page 64 Install. length ball valve Type 230 110-240V AC/DC Type 24 24V AC/DC Install. length ball valve Type 230 24-240V AC/DC 312 APH Techniek BV - Wateringen - T +31 (0)174 219 200 - sales@aphtechniek.nl - www.aphtechniek.nl
RkJQdWJsaXNoZXIy ODY1MjQ=